// Copyright 2018 The Periph Authors. All rights reserved. // Use of this source code is governed under the Apache License, Version 2.0 // that can be found in the LICENSE file. package mcp9808_test import ( "fmt" "log" "periph.io/x/conn/i2c/i2creg" "periph.io/x/conn/physic" "periph.io/x/devices/mcp9808" "periph.io/x/host" ) func ExampleDev_SenseTemp() { // Make sure periph is initialized. if _, err := host.Init(); err != nil { log.Fatal(err) } // Open default I²C bus. bus, err := i2creg.Open("") if err != nil { log.Fatalf("failed to open I²C: %v", err) } defer bus.Close() // Create a new temperature sensor. sensor, err := mcp9808.New(bus, &mcp9808.DefaultOpts) if err != nil { log.Fatalln(err) } // Read values from sensor. measurement, err := sensor.SenseTemp() if err != nil { log.Fatalln(err) } fmt.Println(measurement) } func ExampleDev_SenseWithAlerts() { // Make sure periph is initialized. if _, err := host.Init(); err != nil { log.Fatal(err) } // Open default I²C bus. bus, err := i2creg.Open("") if err != nil { log.Fatalf("failed to open I²C: %v", err) } defer bus.Close() // Create a new temperature sensor. sensor, err := mcp9808.New(bus, &mcp9808.DefaultOpts) if err != nil { log.Fatalln(err) } lower := physic.ZeroCelsius upper := physic.ZeroCelsius + 25*physic.Celsius critical := physic.ZeroCelsius + 32*physic.Celsius // Read values from sensor. temperature, alerts, err := sensor.SenseWithAlerts(lower, upper, critical) if err != nil { log.Fatalln(err) } for _, alert := range alerts { fmt.Println(alert) } fmt.Println(temperature) }