// Copyright 2017 The Periph Authors. All rights reserved.
|
|
// Use of this source code is governed under the Apache License, Version 2.0
|
|
// that can be found in the LICENSE file.
|
|
|
|
package cap1188
|
|
|
|
import (
|
|
"errors"
|
|
|
|
"periph.io/x/periph/conn/gpio"
|
|
)
|
|
|
|
// SamplingTime determines the time to make a single sample.
|
|
type SamplingTime uint8
|
|
|
|
const (
|
|
S320us SamplingTime = 0
|
|
S640us SamplingTime = 1
|
|
// S1_28ms represents 1.28ms sampling time, which is the default.
|
|
S1_28ms SamplingTime = 2
|
|
S2_56ms SamplingTime = 3
|
|
)
|
|
|
|
// AvgSampling set the number of samples per measurement that get averaged.
|
|
type AvgSampling uint8
|
|
|
|
const (
|
|
// Avg1 means that 1 sample is taken per measurement
|
|
Avg1 AvgSampling = iota // 0
|
|
Avg2 // 1
|
|
Avg4 // 2
|
|
Avg8 // 3 default
|
|
Avg16 // 4
|
|
Avg32 // 5
|
|
Avg64 // 6
|
|
Avg128 // 7
|
|
)
|
|
|
|
// CycleTime determines the overall cycle time for all measured channels during
|
|
// normal operation.
|
|
type CycleTime uint8
|
|
|
|
// Possible cycle time values. (written as 2 bits)
|
|
const (
|
|
C35ms CycleTime = iota // 0
|
|
C70ms // default
|
|
C105ms
|
|
C140ms
|
|
)
|
|
|
|
// MaxDur is the maximum duration of a touch event before it triggers a
|
|
// recalibration.
|
|
type MaxDur uint8
|
|
|
|
// Possible touch duration values. (written as 4 bits)
|
|
const (
|
|
MaxDur560ms MaxDur = iota
|
|
MaxDur840ms
|
|
MaxDur1120ms
|
|
MaxDur1400ms
|
|
MaxDur1680ms
|
|
MaxDur2240ms
|
|
MaxDur2800ms
|
|
MaxDur3360ms
|
|
MaxDur3920ms
|
|
MaxDur44800ms
|
|
MaxDur5600ms // default
|
|
MaxDur6720ms
|
|
MaxDur7840ms
|
|
MaxDur8906ms
|
|
MaxDur10080ms
|
|
MaxDur11200ms
|
|
)
|
|
|
|
// Opts is options to pass to the constructor.
|
|
type Opts struct {
|
|
// Debug turns on extra logging capabilities.
|
|
Debug bool
|
|
// I2CAddr is the I²C slave address to use. It can only used on creation of
|
|
// an I²C-device. Its default value is 0x28. It can be set to other values
|
|
// (0x29, 0x2a, 0x2b, 0x2c) depending on the HW configuration of the
|
|
// ADDR_COMM pin. Must not be set when used over SPI.
|
|
I2CAddr uint16
|
|
// LinkedLEDs indicates if the LEDs should be activated automatically
|
|
// when their sensors detect a touch event.
|
|
LinkedLEDs bool
|
|
// MaxTouchDuration sets the touch duration threshold. It is possible that a
|
|
// “stuck button” occurs when something is placed on a button which causes a
|
|
// touch to be detected for a long period. By setting this value, a
|
|
// recalibration can be forced when a touch is held on a button for longer
|
|
// than the duration specified.
|
|
MaxTouchDuration MaxDur
|
|
// EnableRecalibration is used to force the recalibration if a touch event
|
|
// lasts longer than MaxTouchDuration.
|
|
EnableRecalibration bool
|
|
|
|
// AlertPin is the pin receiving the interrupt when a touch event is detected
|
|
// and optionally if a release event is detected.
|
|
AlertPin gpio.PinIn
|
|
// ResetPin is the pin used to reset the device.
|
|
ResetPin gpio.PinOut
|
|
|
|
// InterruptOnRelease indicates if the device should also trigger an
|
|
// interrupt on the AlertPin when a release event is detected.
|
|
InterruptOnRelease bool
|
|
|
|
// RetriggerOnHold forces a retrigger of the interrupt when a sensor is
|
|
// pressed for longer than MaxTouchDuration
|
|
RetriggerOnHold bool
|
|
|
|
// Averaging and Sampling Configuration Register.
|
|
|
|
// SamplesPerMeasurement is the number of samples taken per measurement. All
|
|
// samples are taken consecutively on the same channel before the next
|
|
// channel is sampled and the result is averaged over the number of samples
|
|
// measured before updating the measured results.
|
|
// Available options: 1, 2, 4, 8 (default), 16, 32, 64, 128
|
|
SamplesPerMeasurement AvgSampling
|
|
|
|
// SamplingTime Determines the time to take a single sample as shown.
|
|
SamplingTime SamplingTime
|
|
|
|
// CycleTime determines the overall cycle time for all measured channels
|
|
// during normal operation. All measured channels are sampled at the
|
|
// beginning of the cycle time. If additional time is remaining, then the
|
|
// device is placed into a lower power state for the remaining duration of
|
|
// the cycle.
|
|
CycleTime CycleTime
|
|
}
|
|
|
|
func (o *Opts) i2cAddr() (uint16, error) {
|
|
switch o.I2CAddr {
|
|
case 0:
|
|
// Default address.
|
|
return 0x28, nil
|
|
case 0x28, 0x29, 0x2a, 0x2b, 0x2c:
|
|
return o.I2CAddr, nil
|
|
default:
|
|
return 0, errors.New("given address not supported by device")
|
|
}
|
|
}
|
|
|
|
// DefaultOpts contains default options to use.
|
|
var DefaultOpts = Opts{
|
|
LinkedLEDs: true,
|
|
MaxTouchDuration: MaxDur5600ms,
|
|
RetriggerOnHold: false,
|
|
EnableRecalibration: false,
|
|
InterruptOnRelease: false,
|
|
SamplesPerMeasurement: Avg1,
|
|
SamplingTime: S1_28ms,
|
|
CycleTime: C35ms,
|
|
}
|