# Sensirion SCD4x CO<sub>2</sub> Sensors
|
|
|
|
## Overview
|
|
|
|
This package provides a driver for the Sensirion SCD4x CO<sub>2</sub> sensors. This is a
|
|
compact sensor that provides temperature, humidity, and CO<sub>2</sub> concentration
|
|
readings. The datasheet for this device is available at:
|
|
|
|
https://sensirion.com/media/documents/48C4B7FB/66E05452/CD_DS_SCD4x_Datasheet_D1.pdf
|
|
|
|
## Testing
|
|
|
|
The unit tests can function with either a live sensor, or in playback mode. If the
|
|
environment variable SCD4X is set, then the self test code will use a live
|
|
sensor on the default I<sup>2</sup>C bus. For example:
|
|
|
|
```bash
|
|
$> SCD4X=1 go test -v
|
|
```
|
|
If the environment variable is not present, then unit tests will be conducted using
|
|
playback values.
|
|
|
|
## Notes
|
|
|
|
### Acquisition Time
|
|
|
|
The minimum acquisition time for the sensor is 5 seconds. If you call Sense() more
|
|
frequently, it will block until a reading is ready.
|
|
|
|
### Forced Calibration and Self-Test
|
|
|
|
These functions are not implemented. From examining the datasheet, and
|
|
experimenting, it appears that these two calls require the i2c communication
|
|
driver to wait a specified period before initiating the read. The periph.io
|
|
I<sup>2</sup>C library doesn't support this functionality. This means that attempts
|
|
to call these functions will always fail so they're not implemented.
|
|
|
|
### Acquisition Mode
|
|
|
|
Only certain commands can be issued while the device is running in acquisition
|
|
mode. If you're working on the low-level code, be aware that attempts to send
|
|
a non-allowed command while in acquisition mode will return an i2c remote
|
|
io-error.
|
|
|
|
### Automatic Self Calibration
|
|
|
|
When Automatic Self Calibration is enabled, and the sensor has run for the
|
|
required period, it will adjust itself so that the LOWEST recorded reading
|
|
during the period yields the value set for ASC Target. The factory default
|
|
target is 400PPM, but the current PPM is ~425PPM. To get a more accurate
|
|
value for CO2 concentration in Earth's atmosphere, refer to:
|
|
|
|
https://www.co2.earth/daily-co2
|
|
|
|
For more details, refer to the datasheet.
|
|
|